Transformer Demagnetization: Causes, Detection, and Prevention

2024-05-09

Transformer demagnetization, although less typical than other transformer problems, positions significant threats to the functional integrity and effectiveness of power systems. Therefore, understanding the root causes of transformer demagnetization is essential for applying efficient monitoring and maintenance methods.

 

Key Points

– Primary causes of transformer demagnetization

– Effects of demagnetization on transformer performance

– Methods to detect transformer demagnetization

– Techniques for re-magnetizing transformers

– Preventative measures to avoid demagnetization

 

Transformer Demagnetization: What Causes it?

The core of a transformer is generally constructed from materials that display magnetic properties, like silicon steel, which are necessary for the makeover of electrical power. Demagnetization takes place when these magnetic properties are impaired or altered. The key reasons for transformer demagnetization include:

Reasons Description
DC Predisposition A DC bias occurs when straight existing infiltrates an AC system, leading to the saturation of the transformer core. This condition not only minimizes the core’s magnetic construction but can permanently change its magnetization state.
Electrical Faults Short circuits and other electrical faults can create extreme current flow with the transformer. Such events can produce heat and create magnetic fields solid sufficient to partly demagnetize the core.
Geometric Stress and Anxiety Physical damage or contortion of the transformer core, often because of mechanical stress and anxiety or poor handling, can interrupt the positioning of the magnetic domains and bring about demagnetization.
Outside Magnetic Area Solid outside electromagnetic fields, whether from close-by electric equipment or transient geomagnetic disturbances, can generate opposing electromagnetic fields in a transformer’s core, thus affecting its magnetization.
Thermal Aging Too much temperature levels in time can create thermal degradation of the core product. This deterioration not only decreases the core’s leaks in the structure but can additionally result in a loss of magnetization.

Each of these factors can individually or collectively add to the phenomenon of transformer demagnetization. Efficient monitoring and precautionary measures are vital to minimizing these risks and ensuring the long life and performance of transformers.

Transformer Demagnetization

 

Transformer Demagnetization: How to Detect it?

Discovering transformer demagnetization is important for keeping reliable performance and preventing expensive downtime. Several techniques can be utilized to accurately identify this problem. They are:

1. Dimension of Excitation Current

By determining the excitation current required to get to a detailed voltage level during testing, anomalies showing demagnetization can be determined. A higher than regular excitation current is a strong sign of demagnetization issues.

2. Detection of Uneven Saturation

In a demagnetized transformer core, the recurring flux causes the core to saturate asymmetrically when a rotating voltage is used. Observing this crookedness in the magnetization curve can expose the existence of demagnetization.

3. Recuperation Voltage Method

After using a DC voltage to the transformer windings, the core magnetizes. Getting rid of the voltage creates a recuperation voltage to show up, which is symmetrical to the degree of magnetization. Contrasting the healing voltage against understood values assists in determining if demagnetization exists.

4. Analysis of Hysteresis Loop

Taking a look at the hysteresis loop of the transformer’s core material offers an understanding of its magnetic state. Distortions in the loophole can highlight demagnetization effects and aid gauge the severity of the condition.

5. Regularity Feedback Evaluation (FRA)

This strategy recognizes modifications in the transformer’s core by applying a variety of regularities to its winding. Variations in the action can pinpoint prospective demagnetization concerns.

Methods Principle Trick Indicator
Measurement of Excitation Current Steps the excitation current needed for a certain voltage level Greater than normal excitation current
Discovery of Uneven Saturation Observe the core’s crooked saturation behavior Asymmetry in magnetization contour
Healing Voltage Method Examines healing voltage after getting rid of a DC voltage Lower than anticipated recuperation voltage
Analysis of Hysteresis Loop Examines distortions in the core’s hysteresis loop Substantial loophole distortions
Regularity Action Evaluation Applies a series of regularities to winding and evaluates action Inconsistencies in anticipated frequency response

 

Transformer Demagnetization: How to Re-magnetize it?

Re-magnetizing transformers is an important procedure to restore their ideal efficiency by adhering to demagnetization. This condition can develop as a result of numerous disruptions like DC currents, lightning strikes, or functional faults. The methods entailed in re-magnetizing transformers have to be diligently related to guarantee the transformer returns to its full practical capacity without sustaining additional damage.

1. Application of AC Change

One usual approach to re-magnetize a transformer includes the application of rotating existing (AC) flux. This strategy utilizes a controlled boost of a/c existing to generate a magnetic field within the core, gradually straightening the magnetic domains. It’s critical to regulate the voltage and frequency throughout this procedure to prevent excessive currents that might lead to overheating or additional tension on the transformer’s winding.

2. Direct Present Shot

Another method is direct current (DC) injection, where a DC resource is used straight to the transformer windings. The DC assists in establishing the magnetic domain names in the proper orientation. The quantity of current and the duration of the application are important factors that need cautious calibration based on the dimension and kind of the transformer to avoid core saturation or various other unfavorable impacts.

3. Usage of External Magnets

Making use of exterior magnets is a much less common but effective technique for re-magnetizing smaller transformers. Solid permanent magnets are placed near the transformer core, causing a magnetic area that can aid realign the transformer’s magnetic domain names. This technique is typically scheduled for specific circumstances where typical re-magnetization techniques may not be viable.

4. Demagnetization Cycles

In particular instances, carrying out a collection of demagnetization cycles can help in re-magnetizing a transformer. This procedure includes using an air conditioner current that progressively reduces in amplitude. Each cycle is developed to decrease recurring magnetism incrementally until the core is counteracted, after which an appropriate re-magnetization method is put in to bring back the core’s magnetic properties.

Implementing these strategies calls for accurate control and keeping an eye on to ensure performance and to prevent triggering additional damage to the transformer. The selection of method depends on the certain attributes of the transformer and the nature of the demagnetization that has occurred. Each strategy has its advantages and limitations, and typically, a mix of these methods is utilized to achieve the best results.

Transformers

 

Transformer Demagnetization: How to Avoid it?

Demagnetization of transformers can bring about substantial performance issues, making it vital to take on safety nets to maintain the honesty and efficiency of these essential parts in the power distribution network. Focusing on transformer demagnetization avoidance not only boosts the long life of the transformers but also ensures their functional integrity.

1. Maintaining and Checking Routines

Routine maintenance is critical in stopping demagnetization. It consists of routine inspections and screening to recognize any type of prospective concerns that might bring about demagnetization early. Executing a regular maintenance timetable assists in keeping an eye on the transformer’s condition and guaranteeing that it runs within the specified parameters.

2. Use Safety Instruments

Mounting safety gadgets is necessary to secure transformers from external aspects that can create demagnetization. Surge protectors, for instance, avoid high voltage spikes that may demagnetize the core. In the following table, we highlight some generally utilized safety tools:

Tools Feature Influence On Demagnetization Avoidance
Surge Protectors Blocks or draws away high voltage spikes High
Harmonic Filters Reduces power system harmonics Medium
Magnetic Circuit Breakers Disconnects power in case of overload Medium

3. Enhanced Transformer Layout and Product Selection

Enhancing transformer layout and choosing the appropriate materials play a substantial role in minimizing the danger of demagnetization. Using premium magnetic cores and durable insulation materials can dramatically lower sensitivity to magnetic tensions and environmental variables that add to demagnetization.

4. Control of Functional Conditions

Regulating the operational conditions to avoid situations that can cause transformer demagnetization is vital. This consists of tracking and managing tons of currents and avoiding long-term operations under severe problems. It is necessary to ensure that transformers do not operate past their design specs, such as voltage and current scores.

5. Worker Training

Training employees on the risks connected with demagnetization and the importance of safety nets is vital. Recognition and understanding of how demagnetization impacts transformer performance and the associated threats help in promoting methods that prevent such concerns.

By implementing these preventative measures, it is feasible to dramatically minimize the threat of transformer demagnetization and ensure the effective and reliable performance of transformers in the power circulation network.

Transformer Inspection

 

FAQs about Transformer Demagnetization

1. What are the primary causes of transformer demagnetization?

The primary causes of transformer demagnetization include DC Bias, Electrical Faults, Geometric Stress, External Magnetic Fields, and Thermal Aging.

2. What are the effects of demagnetization on transformer performance?

Demagnetization in transformers can lead to several adverse effects on their performance, including an increase in core losses, degradation of voltage regulation, increased audible noise and vibrations, thermal issues, and compromised dynamic response to system disturbances.

3. What are the methods to detect transformer demagnetization?

The methods to detect transformer demagnetization include measurement of excitation current, detection of asymmetric saturation, recovery voltage method, analysis of hysteresis loop, and frequency response analysis (FRA).

4. What are the techniques for re-magnetizing transformers?

The techniques for re-magnetizing transformers include the application of AC Flux, direct current injection, utilization of external magnets, and demagnetization cycles.

5. What are the preventative measures to avoid the demagnetization of transformers?

Preventative measures to avoid demagnetization of transformers include regular maintenance and testing routines, use of protective devices, optimized transformer design and material selection, control of operational conditions, and training and awareness.

  • 请在浏览器中启用JavaScript来完成此表单。
    Please leave the following information for quicker reply: product name, specifications, quantity, usage, etc.
  • Get Inquiry
  • 请在浏览器中启用JavaScript来完成此表单。
    Please leave the following information for quicker reply: product name, specifications, quantity, usage, etc.
  • Get Inquiry
  • 请在浏览器中启用JavaScript来完成此表单。
    Please leave the following information for quicker reply: product name, specifications, quantity, usage, etc.